View allAll Photos Tagged Generators
Enson vesivoimalan generaattoria asennetaan tai huolletaan.
photographer unknown / kuvaaja tuntematon
1920-1945
Enso, Etelä-Karjala, Finland / Suomi
Finnish Museum of Photography / Suomen valokuvataiteen museo
This Diesel Generator, together with the Aft Emergency Switchboard nearby, supplied emergency electricity to critical equipment.
Aboard the Battleship North Carolina, at Battleship Park, near Wilmington, North Carolina. I visited here the USS North Carolina (BB 55), a North Carolina-class battleship, now a museum ship. This battleship was launched in 1940, commissioned in 1941 and served in World War II in the Atlantic and Pacific theaters. She has been at this location as a museum ship since 1962. I visited this ship on April 13, 2018.
The Skaguay Power Plant, in what is now the Beaver Creek Wilderness Study Area, operated from 1901 to 1965
Read more: www.gazette.com/articles/canyon-37887-skaguay-power.html#...
An original generator installed sometime in the early 1940's when La Coupole was in its final stages of completion
Dungeness B turbine Generator 22 has been undergoing a planned Statutory outage three-yearly maintenance shutdown and according to EDF is not expected to return to service until the week comencing the 24 August 2015. This then is the first working of the Crewe Coal Sidings to Dungeness and return service for some time.
Here Direct Rail Services class 20 number 20305 (formerly D8095 and 20095) named "Gresty Bridge" is photographed on the Up Chatham Fast leading 20 number 309 working 6M95 on 29 May 2015. It was built in 1961 by Robert Stephenson & Hawthorn Ltd, Darlington.
it was also photographed later on route by papercliponawire at Earls Court.
Te-Chi Reservoir 德基水庫
At 180 meters high and 290 meters in length, with a storage capacity of more than 175,000,000 cubic meters, Te-Chi Dam is one of the largest/tallest dams in the world. Construction of the dam was started in 1969 by the Taiwan Power Company and was completed five years later in 1974. Its power station contains three 78 MW generators for a total installed capacity of 234 MW.
德基水庫大壩180公尺高、290公尺寬,有效蓄水量17,500百萬立方米,是台灣蓄水量第四大的水庫,也是世界十大水壩之一。1969年開工,1974年完工,德基水庫有三座78,000千瓦的發電機,總容量達234,000千瓦,年發電量約4億度。
Hoping District, Taichung City 台中市和平區
Monsters generator for Uovo Kids festival.
Project in collaboration with Zetalab & artigianato digitale.
More:
A demonstration of a hybrid generator prototype that combines solar, wind, and a fuel cell battery with a fuel-run generator at the Project Manager Mobile Electric Power (PM MEP) Users’ Conference 5 May 2010 in Orlando, Fla. The image was electronically altered. Portions of image blurred
Unfortunately I am not allow to take photos of the Generator sets that I work on at Cummins Power Generation, so this is the closest I can get - a photo taken from the internet. At least it gives an idea of the sort of kit I am testing up to full load - ear defenders a must!!!!
(Although this is most probably a QSK60 with a 3201 panel and is bigger than those I currently test, the biggest being a KTA50)
Read the nameplate, said it generated a higher frequency AC from 60 cycle power.Steel mills use a lot of different voltages & frequencies for their machinery.Picture taken 1990.
25-100 kva Cummins Diesel Generator General Features
1. Every generator set is subjected to a comprehensive test program which includes 50% load, 75% load, 100% load, 110% load and the checking and proving of all control and safety shut-down functions.
2. Equipped with battery charger and 24V high performance maintenance-free lead-acid starting batteries and connecting with cables.
3. Equipped with industrial silencer and flexible exhaust hose.
4. Equipped with 8-hours operation base tank.
5. Equipped with CHINT MCCB circuit breaker.
6. Designed to Comply with ISO8528/GB2820.
7. Powered by Cummins engine and coupled with Stamford alternator.
MPMC has good diesel generators for sale, if you need some information, you can email to us.
Cummins Open Diesel Generator Control System DSE3110
All MPMC series genset have a control cubicle (the deepsea controller DSE3110 as standard) mounted on a isolated support, which has the following features:
1. Electronic digital control module with monitoring/control facility and warning indicators.
2. Automatic shutdown protection.
3. Emergency stop button (lock-down type).
4. AC output circuit breaker with over-current protection.
5. DC circuit control switch.
Iveco Power Generator Set Options and Accessories
Generator set
Silence generator set
Trailer generator set
ABB MCCB circuit breaker
Fuel system
12 hour base tank(single wall)
24 hour base tank(single wall)
Dual wall base fuel tank
Outside fuel tank
Exhaust system
Residential exhaust silencer
Alternator
PMG excitation
Space heater
Low environment temperature
Water heater
Oil heater
Battery heater
Control system
AMF function
ATS control cabinet
Multiple generator automatic synchrorising.
Control System DSE3110
The control module gives digital readouts of:
1. Engine speed
2. Generator voltage
3. Battery voltage
4. Output frequency
5. Engine hours run.
All MPMC series genset have a control cubicle (the deepsea controller DSE3110 as standard) mounted on a isolated support, which has the following features:
1. Emergency stop button (lock-down type)
2. AC output circuit breaker with over-current protection
3. Electronic digital control module with monitoring/control facility and warning indicators
4. Automatic shutdown protection
5. DC circuit control switch.
Note:
1. The engine coolant temperature used temperature meter display
2. The engine oil pressure used oil pressure meter display
3. Generator current used current meter display and used change switch for each phase displayed separately.
Automatic shutdown occurs under:
1. Low engine oil pressure
2. High engine water temperature
3. Overspeed/underspeed
4. Failure to start after three attempts.
The control module has indicators for failure information:
1. Overspeed/underspeed
2. Failure to start
3. Low oil pressure
4. Battery charger failure
5. Emergency stop
6. High water temperature.
These are Hoover Dam's Nevada-side hydroelectric generators. To get a sense of the scale, notice the stairs leading up to the top of the nearest one.
Co-Worker Paul is adding a hydrogen generator to his car, will it work, I'll let you know when I do.
22 LUGLIO - Francesco Scianna in Sala Truffaut incontra le giurie Generator e riceve il Premio Truffaut.
General Features of Volvo Diesel Generator
1. Powered by Volvo engine and coupled with Stamford alternator.
2. Prime Power: This rating is for the supply of continuous electrical power (at variable load). There is no limit on the annual hours of operation and 10% overload power can be supplied for 1 hour in 12.
3. Standby power: This rating is for the supply of continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted.
4. Rated voltage: Available with customer requirements.
5. Every generator set is subjected to a comprehensive test program which includes 50% load, 75% load, 100% load, 110% load and the checking and proving of all control and safety shut-down functions.
6. Equipped with battery charger and 12V high performance maintenance-free lead-acid starting batteries and connecting with cables.
7. Equipped with industrial silencer and flexible exhaust hose.
8. Equipped with 8-hours operation base tank.
9. Equipped with CHINT MCCB circuit breaker.
10. Designed to Comply with ISO8528/GB2820.
Volvo, the largest industrial enterprise in Sweden with more than 120 years' history, is an engine manufacturer with the longest history in the world. Up to the present, its engine filed products exceed 1 million sets and have been widely used in large and small automobiles, heavy-duty trucks, engineering machineries and ships. Moreover, they are the ideal drive force of power generation sets. Volvo engines have high load capability as well as fast and reliable cold start performance.
Millennium Power can provide a wide range of Volvo generator.
MPMC reserves the right to implement specifications or design changes without notice.
WARNING: Do not connect generator to any building's electrical system unless a disconnect switch has been installed.