View allAll Photos Tagged PROFIBUS

DATAEAGLE 3000 Series / Wireless Profibus / 2.4GHz

www.m2m-dynamics.com/?page_id=519

Redundant Wireless Profibus = 4 independent links working in 2.4Ghz and 900MHz. Equipment used DATAEAGLE 3000 Series Radios.

Designed by M2M-Dynamics and Hatch Engineering.

 

3000 Series, Wireless Profibus Siemens S5 95U -> S5 135u with CP 5432

PUMP STATION

DATAEAGLE Wireless Profibus Install

www.m2m-dynamics.com

wireless profibus dp. For more info on wireless profibus visit us at

www.m2m-dynamics.com/?page_id=23

 

Product Description

We can offer very attractive prices for Siemens S7 series PLC and I/O Modules, ranging from S7-200, S7-300 to S7-400. We are currently supplying Siemens S5 and S7 parts to USA, Europe, South-East Asia, India, Pakistan, Middle East and etc. Please contact us for more details.

Product Feature

S5-100U,115U,155U PLCs

 

S7-200,300,400 PLCs

 

PG,HMI and Wincc

 

ET200M,ET200S,Profibus

 

MM420,MM430,MM440 Variable Speed drive

 

SINUMERIK 810D,SINUMERIK 840D,SINUMERIK 840Di

 

SIMOTION D425,SIMOTION D435,SIMOTION D445

 

SIMOVERT MASTERDRIVES CONVERTER

Product Specification/Models

Most products are in stock!

 

6ES7 407-0DA02-0AA0

6ES7 407-0KA02-0AA0

6ES7 407-0KR02-0AA0

6ES7 407-0RA02-0AA0

6ES7 405-0DA02-0AA0

6ES7 405-0KA02-0AA0

6ES7 405-0RA02-0AA0

6ES7 971-0BA00

 

Creative Groups provides the best PLC Training in Bangalore and Scada Training in Bangalore. We offers the automation training like Plc, Hmi, Vfd Servo Devices forth..,

 

creativegroups.co/

  

PLC Hardware configurations for (PLC,DI,DO,AI,AO,FM MODULE).

⇨ Configuration Profibus or Profinet module GSD on HW configuration.

⇨ MOD BUS Module data Analyzing methods.

⇨ LAD/ STL program instructions.

⇨ FC , FB,DB,UDT,OB , SFC, SFB concepts.

⇨ PLC clock memory , retentive memory, High speed input pulse programs.

⇨ Analog scaling, Un scaling, READ / WRITE DATA from PROFIBUS & PROFINET.

⇨ Indirect address Programming methods.

⇨ Creating source files of program.

⇨ CFC programming.

⇨ SFC programming.

D6003B is a fieldbus receiver for industrial applications in communications between industrial computers, transmitters, sensors and instruments. The receiver comes in two basic models –CAN-bus and Profibus

DATAEAGLE 3000 Series / Wireless Profibus

Participação da Profibus na 10ª edição do ISA Expo Campinas | Seminário e Exposição de Novas Tecnologias em Automação Industrial

Participação da Profibus na 10ª edição do ISA Expo Campinas | Seminário e Exposição de Novas Tecnologias em Automação Industrial

Participação da Profibus na 10ª edição do ISA Expo Campinas | Seminário e Exposição de Novas Tecnologias em Automação Industrial

Participação da Profibus na 10ª edição do ISA Expo Campinas | Seminário e Exposição de Novas Tecnologias em Automação Industrial

Participação da Profibus na 10ª edição do ISA Expo Campinas | Seminário e Exposição de Novas Tecnologias em Automação Industrial

Participação da Profibus na 10ª edição do ISA Expo Campinas | Seminário e Exposição de Novas Tecnologias em Automação Industrial

Participação da Profibus na 10ª edição do ISA Expo Campinas | Seminário e Exposição de Novas Tecnologias em Automação Industrial

Monorail at John Deere. DATAEAGLE 3000 with a master and 5 hangers. Control is Siemens S7 315 DP -to-> The hanger ET200.

Participação da Profibus na 10ª edição do ISA Expo Campinas | Seminário e Exposição de Novas Tecnologias em Automação Industrial

3000 Series, Wireless Profibus Siemens S5 95U -> S5 135u with CP 5432

DATAEAGLE 3000 with Profibus & PROFIsafe radio transmission between the mountain station and cab.

Participação da Profibus na 10ª edição do ISA Expo Campinas | Seminário e Exposição de Novas Tecnologias em Automação Industrial

Participação da Profibus na 10ª edição do ISA Expo Campinas | Seminário e Exposição de Novas Tecnologias em Automação Industrial

Wireless Profisafe

For more info visit www.m2m-dynamics.com

ATV610D18N4 - Biến tần Schneider, thuộc dòng ATV610, điện áp vào 3-phase 380~415VAC 50/60Hz, công suất 18.5kW, dòng định mức 39.2A, công suất 18.5kW, loại tải Tải nhẹ, truyền thông Profibus DP V1 bus, Modbus RS-485, ứng dụng Bơm, Quạt, Băng tải, Các ứng dụng đơn giản. Xem ngay: hoplongtech.com/products/atv610d18n4

Main sponsors: Fieldbus Foundation, HART Communication Foundation, OPC Foundation, PROFIBUS International

 

www.hiconics-global.com/products/6kv-630-12500kw-water-co...

 

Whatever your industry is, Hiconics's medium voltage drive could be an all-rounder to control your standard applications and optimize your processes. Tailor the drive to your specific application by selecting from an extended choice of pre-engineered options. Extensive versatility makes our VFD suitable for operations in different conditions and environments, even hazardous areas. High reliability in your daily business is ensured by the drive's simple design and robust control platform that has proven itself over many years.

Technical Parameters of 6kV/630~12500kW Water-cooled Medium Voltage Drive

VoltageMotor Power(KW)Output Capacity(KVA)ModelWeight

(kg)Dimension

(W*H*D)Cabinet Type

 

6kV630800HIVERT-Y/T 06/077W54505000×1200×2200

5800×1200×2200LAW2.1

LCW2.1

8001000HIVERT-Y/T 06/096W5600

10001250HIVERT-Y/T 06/130W5800

12501600HIVERT-Y/T 06/154W70505850×1200×2300LAW3.1

14001800HIVERT-Y/T 06/173W7350

16002000HIVERT- Y/T 06/192W7660

18002250HIVERT- Y/T 06/220W7960

20002500HIVERT- Y/T 06/243W8310

22502800HIVERT- Y/T 06/275W104107500×1400×2400

7870×1400×2400LAW4.1

LCW4.1

25003200HIVERT- Y/T 06/304W10760

28003500HIVERT- Y/T 06/340W11170

32004000HIVERT-Y/T 06/400W11700

36004500HIVERT-Y/T 06/425W152409300×1600×2400/2800

9700×1600×2400/2800LAW5.1

LCW5.1

40005000HIVERT- Y/T 06 /500W15790

  

Specification of 6kV/630~12500kW Water-cooled Medium Voltage Drive

ItemParameters

VFD rated power210~28000kVA※

Rated voltage3.3kV~11kV(-20%~+5%)※(Out of range, special instructions required)

Rated Frequency50Hz/60Hz(-10%~+10%)※

Control Power380VAC, 30kVA

Rated input power factor≥0.96

Effciency>96%

Output frequency range0~80Hz※

Speed accuracy±0.5%(Open loop vector) ±0.1%(close loop vector)

Instantaneous over-current protection150%( Can be customized according to user requirements)

Over capacity120% load for 120s

Torque limitation10%~150%

Analog input3 ways 4~20mA/Excitation feedback 4~20mA(Customized)

Analog output4ways 4~20mA

Host communicationIsolated RS485 interface, ModBus RTU, Profibus DP(optional), Industry Ethernet

Acceleration and deceleration time5s~6000s ( related to load)

DI14 inputs/22 outputs (Output 8 ways can be defined)

Environment temperature-5~+45℃※

Storage/transportation temperature-25~+55℃※

Cooling methordAir forced cooling (AF) / Water cooled (WF)/Air forced water cooled (AFWF)

Humidity<95%, no condensation

Altitude≤1000m, when altitude is higher than 1000m, each 100 meter increasing needs 1%

derating of VFD

DustNon-conductive, no causticity, <6.5mg/dm3※

Protection levelIP30※

Cabinet colorsRAL 7032(customized)

1 2 4 6 7