Generator parallelizer
New parallel kit for my Honda EU2000i generators.
The old one was simpler and cheaper. But to work with the power protection in the new camper, the ground and neutral need to be tied together. The generators leave the ground floating and the power protector does not like that. Wth the old one I would have to leave a hot plug lying around.
This one allows the cables to the generator to be disconnected. I used L5-20R receptacles, which is the same as what is on the generator. I made two cables with L5-20P plugs on either end. This will be hard for someone to accidently plug into a 15A outlet.
I would have used 15A twist lock connectors on the parallelizer, but they were quite a bit more expensive.