lneyachiller
Air Water Chiller SUNDI-4 For Two Reactors
Display Function
Cooling heating Temperature Control System Display – The Refrigeration system's multi-image displays various information.
ModelSUNDI-425W-2T N
SUNDI-425-2T NSUNDI-435W-2T N
SUNDI-435-2T NSUNDI-455W-2T N
SUNDI-455-2T NSUNDI-475W-2T N
SUNDI-475-2T NSUNDI-4A10W-2T N
SUNDI-4A10-2T N
Temp. range-40°C~+200°C
Control ModeFeedback PID + Our special dynamic control calculation, PLC controller
Temp. controlProcess temp. control and jacket temp. control model TWO GROUPS
Temp. differenceSet or control the temperature difference between jacket oil and raw material process TWO GROUPS
Communication PortocolMODBUS RTU Protocol,RS485 interface
Material temp. feedbackPT100 OR 4~20mA or communication(normal: PT100)
Temp. feedbackthe temp. of three points: the inlet and outlet of equipment, reactor material temp.(external temp. sensor)*2
Medium temp. acccuracy±0.5°C
Material temp. accuracy±1°C
Heating power kW2.5*23.5*25.5*27.5*210*2
Cooling capacity
kW at ℃200 ° C2.5*23.5*25.5*27*210*2
100 ° C2.5*23.5*25.5*27*210*2
20 ° C2.5*23.5*25.5*27*210*2
0°C1.5*22.5*23.5*25*27.5*2
-20 ° C1*21.6*22.1*23*24*2
-35 ° C0.45*20.75*21*21.4*21.8*2
Circulation pump max
L/min bar20*235*235*250*250*2
1.52222
CompressorTecumseh closed compressorEmerson copeland vortex flexible
Expansion valveEmerson thermal expansion valve/danfoss thermal expansion valve.
EvaporatorDANFOSS/KAORI Plate heat exchanger
Operation Panel7-inch touch screen,show temp curve\EXCEL data output
Safety protectionSelf-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.
Closed circulation systemThe whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature.
RefrigerantR404A/R507C, optional: R448A
Connection sizeG3 / 4G3 / 4G3 / 4G3 / 4G1
Water-cooled type W(cooling water@20℃)1200L/H
1.5bar~4bar1400L/H
1.5bar~4bar1700L/H
1.5bar~4bar2100L/H
1.5bar~4bar2500L/H
1.5bar~4bar
Dimension(water type)cm55*95*17070*100*17570*100*17580*120*185100*150*185
Dimension(air type)cm55*95*17055*95*17070*100*17570*100*17580*120*185
weight kg240285345385480
power 380V 50HZ220V 8kW
www.lneya.com/special-chiller/air-water-chiller-sundi-40-...
Air Water Chiller SUNDI-4 For Two Reactors
Display Function
Cooling heating Temperature Control System Display – The Refrigeration system's multi-image displays various information.
ModelSUNDI-425W-2T N
SUNDI-425-2T NSUNDI-435W-2T N
SUNDI-435-2T NSUNDI-455W-2T N
SUNDI-455-2T NSUNDI-475W-2T N
SUNDI-475-2T NSUNDI-4A10W-2T N
SUNDI-4A10-2T N
Temp. range-40°C~+200°C
Control ModeFeedback PID + Our special dynamic control calculation, PLC controller
Temp. controlProcess temp. control and jacket temp. control model TWO GROUPS
Temp. differenceSet or control the temperature difference between jacket oil and raw material process TWO GROUPS
Communication PortocolMODBUS RTU Protocol,RS485 interface
Material temp. feedbackPT100 OR 4~20mA or communication(normal: PT100)
Temp. feedbackthe temp. of three points: the inlet and outlet of equipment, reactor material temp.(external temp. sensor)*2
Medium temp. acccuracy±0.5°C
Material temp. accuracy±1°C
Heating power kW2.5*23.5*25.5*27.5*210*2
Cooling capacity
kW at ℃200 ° C2.5*23.5*25.5*27*210*2
100 ° C2.5*23.5*25.5*27*210*2
20 ° C2.5*23.5*25.5*27*210*2
0°C1.5*22.5*23.5*25*27.5*2
-20 ° C1*21.6*22.1*23*24*2
-35 ° C0.45*20.75*21*21.4*21.8*2
Circulation pump max
L/min bar20*235*235*250*250*2
1.52222
CompressorTecumseh closed compressorEmerson copeland vortex flexible
Expansion valveEmerson thermal expansion valve/danfoss thermal expansion valve.
EvaporatorDANFOSS/KAORI Plate heat exchanger
Operation Panel7-inch touch screen,show temp curve\EXCEL data output
Safety protectionSelf-diagnosis function; freezer overload protection; high pressure switch, overload relay,thermal protection device, liquid low level protection, high temperature protection and temperature fault protection.
Closed circulation systemThe whole system is full closed circulation, there is no oil mist at high temperature and no water vapor at low temperature, pressure do not rise up when system is running. The system will supply oil automatically at low temperature.
RefrigerantR404A/R507C, optional: R448A
Connection sizeG3 / 4G3 / 4G3 / 4G3 / 4G1
Water-cooled type W(cooling water@20℃)1200L/H
1.5bar~4bar1400L/H
1.5bar~4bar1700L/H
1.5bar~4bar2100L/H
1.5bar~4bar2500L/H
1.5bar~4bar
Dimension(water type)cm55*95*17070*100*17570*100*17580*120*185100*150*185
Dimension(air type)cm55*95*17055*95*17070*100*17570*100*17580*120*185
weight kg240285345385480
power 380V 50HZ220V 8kW