Back to photostream

32. CA control

Back of the CA form B control. Unique to this model is the two pin connector. Other models use screw terminals.

Here, we can see where the bellows push against to actuate the switch. Pushing in turns on the compressor.

The temperature control provides an adjustable preload to the bellows, so that the bellows require more or less pressure to actuate the switch.

The defrost control is merely a mechanical offset to the temperature control to extend the range at the warmer end of the scale.

1,252 views
0 faves
0 comments
Uploaded on September 14, 2012
Taken on September 14, 2012